CN 8413
Pumps for liquids, whether or not fitted with a measuring device; liquid elevators
| Code | Description | Unit | Third-country duty | Source |
|---|---|---|---|---|
| Pumps fitted or designed to be fitted with a measuring device | ||||
| 8413 11 00 00 | Pumps for dispensing fuel or lubricants, of the type used in filling stations or in garages | p/st | 1.7% | TARIC |
| 8413 19 | Other | TARIC | ||
| 8413 19 00 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 19 00 90 | Other | p/st | 1.7% | TARIC |
| 8413 20 | Handpumps, other than those of subheading 8413 11 or 8413 19 | TARIC | ||
| 8413 20 00 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 20 00 90 | Other | p/st | 1.7% | TARIC |
| 8413 30 | Fuel, lubricating or cooling medium pumps for internal combustion piston engines | TARIC | ||
| 8413 30 20 | Injection pumps | TARIC | ||
| 8413 30 20 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 30 20 30 | Single-cylinder radial-piston high pressure pump for gasoline direct injection with: - an operating pressure of 200 bar or more, but not more than 350 bar, - a flow control, and - a pressure relief valve, for use in the manufacture of engines of motor vehicles | p/st | 1.7% | TARIC |
| 8413 30 20 40 | High-pressure plunger pump for direct diesel injection, with: -an operating pressure of not more than 275 MPa, -a camshaft, -a fluid discharging of 15 cm³ per minute or more, but not more than 1 800 cm³ per minute, -an electric pressure regulating valve | p/st | 1.7% | TARIC |
| 8413 30 20 60 | High-pressure plunger pump for direct petrol injection: -with an operating pressure of not more than 90 MPa, -designed to contact the crankshaft, -with an electromagnetic valve | p/st | 1.7% | TARIC |
| 8413 30 20 90 | Other | p/st | 1.7% | TARIC |
| 8413 30 80 | Other | TARIC | ||
| 8413 30 80 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 30 80 20 | Electric water pump ensuring the functionality of the water circuit also when the motor is temporarily switched off, for operating DC voltage of 9 V or more but not more than 16 V, with: -capacity - pressure 0,075 MPa at 3 800 rpm, -discharge of 12 l/min, -whether or not with connecting cable with connector, and -mounting bracket, for use in the manufacture of goods of Chapter 87 | p/st | 1.7% | TARIC |
| 8413 30 80 90 | Other | p/st | 1.7% | TARIC |
| 8413 40 00 00 | Concrete pumps | p/st | 1.7% | TARIC |
| 8413 50 | Other reciprocating positive displacement pumps | TARIC | ||
| 8413 50 20 | Hydraulic units | TARIC | ||
| 8413 50 20 10 | For use in civil aircraft | 0% (end-use) | TARIC | |
| 8413 50 20 90 | Other | 1.7% | TARIC | |
| 8413 50 40 | Dosing and proportioning pumps | TARIC | ||
| 8413 50 40 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 50 40 90 | Other | p/st | 1.7% | TARIC |
| Other | ||||
| Piston pumps | ||||
| 8413 50 61 | Hydraulic fluid power | TARIC | ||
| 8413 50 61 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 50 61 90 | Other | p/st | 1.7% | TARIC |
| 8413 50 69 | Other | TARIC | ||
| 8413 50 69 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 50 69 90 | Other | p/st | 1.7% | TARIC |
| 8413 50 80 | Other | TARIC | ||
| 8413 50 80 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 50 80 90 | Other | p/st | 1.7% | TARIC |
| 8413 60 | Other rotary positive displacement pumps | TARIC | ||
| 8413 60 20 | Hydraulic units | TARIC | ||
| 8413 60 20 10 | For use in civil aircraft | 0% (end-use) | TARIC | |
| 8413 60 20 90 | Other | 1.7% | TARIC | |
| Other | ||||
| Gear pumps | ||||
| 8413 60 31 | Hydraulic fluid power | TARIC | ||
| 8413 60 31 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 31 90 | Other | p/st | 1.7% | TARIC |
| 8413 60 39 | Other | TARIC | ||
| 8413 60 39 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 39 90 | Other | p/st | 1.7% | TARIC |
| Vane pumps | ||||
| 8413 60 61 | Hydraulic fluid power | TARIC | ||
| 8413 60 61 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 61 90 | Other | p/st | 1.7% | TARIC |
| 8413 60 69 | Other | TARIC | ||
| 8413 60 69 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 69 90 | Other | p/st | 1.7% | TARIC |
| 8413 60 70 | Screw pumps | TARIC | ||
| 8413 60 70 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 70 90 | Other | p/st | 1.7% | TARIC |
| 8413 60 80 | Other | TARIC | ||
| 8413 60 80 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 60 80 90 | Other | p/st | 1.7% | TARIC |
| 8413 70 | Other centrifugal pumps | TARIC | ||
| Submersible pumps | ||||
| 8413 70 21 00 | Single-stage | p/st | 1.7% | TARIC |
| 8413 70 29 00 | Multi-stage | p/st | 1.7% | TARIC |
| 8413 70 30 00 | Glandless impeller pumps for heating systems and warm water supply | p/st | 1.7% | TARIC |
| Other, with a discharge outlet diameter | ||||
| 8413 70 35 | Not exceeding 15 mm | TARIC | ||
| 8413 70 35 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 35 89 | Other | p/st | 1.7% | TARIC |
| Exceeding 15 mm | ||||
| 8413 70 45 | Channel impeller pumps and side channel pumps | TARIC | ||
| 8413 70 45 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 45 90 | Other | p/st | 1.7% | TARIC |
| Radial flow pumps | ||||
| Single-stage | ||||
| With single entry impeller | ||||
| 8413 70 51 | Monobloc | TARIC | ||
| 8413 70 51 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 51 20 | Electric brushless direct current motor with single-stage, radial flow pump centrifugal single entry impeller mounted on motor's shaft and volute with integrated heater of nominal power of 1800 W and soldered safety devices, monobloc with the motor, with: -a discharge outlet diameter of 20 mm or more, -9 slots stator, -6 pole rotor, -rated power of 95 W, -volute with straight outlet, -rotor chamber without sand filter | p/st | 1.7% | TARIC |
| 8413 70 51 30 | Electric brushless direct current motor with single-stage, radial flow pump centrifugal single entry impeller mounted on motor's shaft and volute with integrated heater of nominal power of 1800 W and soldered safety devices, monobloc with the motor, with: -a discharge outlet diameter of 20 mm or more, -9 slots stator, -6 pole rotor, -rated power of 95 W, -volute with clamped rubber hose outlet, -rotor chamber without sand filter | p/st | 1.7% | TARIC |
| 8413 70 51 40 | Electric brushless direct current motor with single-stage, radial flow pump centrifugal single entry impeller mounted on motor's shaft, monobloc with the motor, volute with integrated heater, with: -a discharge outlet diameter of 20 mm or more, -9 slots square or chain pole stator, -6 pole rotor, -ferritic or rare earth magnets, -rated power of 95 W or 80 W, -heater of nominal power of 1800 W and soldered or laser welded safety, devices, -volute with or without clamped rubber outlet, -rotor chamber with ultrasonic welded sand filter | p/st | 1.7% | TARIC |
| 8413 70 51 90 | Other | p/st | 1.7% | TARIC |
| 8413 70 59 | Other | TARIC | ||
| 8413 70 59 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 59 90 | Other | p/st | 1.7% | TARIC |
| 8413 70 65 | With more than one entry impeller | TARIC | ||
| 8413 70 65 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 65 90 | Other | p/st | 1.7% | TARIC |
| 8413 70 75 | Multi-stage | TARIC | ||
| 8413 70 75 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 75 90 | Other | p/st | 1.7% | TARIC |
| Other centrifugal pumps | ||||
| 8413 70 81 | Single-stage | TARIC | ||
| 8413 70 81 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 81 90 | Other | p/st | 1.7% | TARIC |
| 8413 70 89 | Multi-stage | TARIC | ||
| 8413 70 89 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 70 89 90 | Other | p/st | 1.7% | TARIC |
| Other pumps; liquid elevators | ||||
| 8413 81 | Pumps | TARIC | ||
| 8413 81 00 10 | For use in civil aircraft | p/st | 0% (end-use) | TARIC |
| 8413 81 00 90 | Other | p/st | 1.7% | TARIC |
| 8413 82 00 00 | Liquid elevators | p/st | 1.7% | TARIC |
| Parts | ||||
| 8413 91 | Of pumps | TARIC | ||
| 8413 91 00 10 | For use in civil aircraft | 0% (end-use) | TARIC | |
| 8413 91 00 30 | Fuel pump cover: - consisting of aluminum alloys, - with a diameter of 38 mm or 50 mm, - with two concentric, annular grooves formed on its surface, - anodized, of a kind used in motor vehicles with petrol engines | p/st | 1.7% | TARIC |
| 8413 91 00 50 | Pump head for two cylinder high pressure pump made of forged steel, with: - milled threaded fittings with a diameter of 10 mm or more but not more than 36,8 mm, and - drilled fuel channels with a diameter of 3,5 mm or more but not more than 10 mm of a kind used in diesel injection systems | p/st | 1.7% | TARIC |
| 8413 91 00 90 | Other | 1.7% | TARIC | |
| 8413 92 00 00 | Of liquid elevators | 1.7% | TARIC | |
The table scrolls sideways.
Source: European Commission (DG TAXUD), TARIC and Combined Nomenclature data as extracted on 1 October 2026. Heading 8413 in the TARIC consultation
Only the third-country duty is shown. Not shown: tariff preferences, quotas, suspensions, anti-dumping and other additional duties, import controls and the legal notes. The TARIC consultation lists the measures of each code.
This page is general information, not legal advice and not a classification decision. Tariff texts and rates change: check the publisher's current schedule, and ask the customs authority for a binding ruling where the answer matters.